Sale!

CT11T7F10PN1 General Electric

¥666.00

CT11T7F10PN1 General Electric
Brand: General Electric
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

CT11T7F10PN1 General Electric
CT11T7F10PN1 General Electric
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com

1、 Why can”t I exceed the speed limit?
1) During the operation of the steam turbine, the centrifugal force on the blade is proportional to the square of the rotating speed, that is to say, although the rotating speed increases slightly, the centrifugal force on the rotor increases geometrically, which is taken into account when the steam turbine is designed, so the overspeed phenomenon is extremely dangerous to the steam turbine.
2) During the design and manufacturing process, the rotor of the rotating machine will have its own self-vibration frequency, which is the frequency corresponding to the critical speed that we should pay attention to when we rush. Therefore, the normal working speed of steam turbine is not within the range of critical speed. However, when the turbine speed exceeds the working speed and reaches twice the frequency of the rotor itself, the vibration of the unit will greatly increase, even greater than the vibration of the unit over the critical speed. Because of the friction between the dynamic and static parts caused by the large vibration of the unit, the vibration of the unit will continue to increase, which leads to a vicious cycle. In serious cases, the steam turbine will be completely scrapped.
3) If the unit is used for power generation, since the grid frequency in China is set at 50Hz, the corresponding turbine speed should also be 3000rpm. If the unit does not work at the rated speed, it will not be able to operate in parallel with the grid. Even in the isolated network operation, if the frequency increases, it will directly lead to the corresponding increase in the rotating speed of the rotating machinery, which will damage the normal operation of the motor, cause the abnormal increase in the output of the pump or fan, make the motor heat, increase the vibration of the pump or fan, and easily lead to the burning accident. At the same time, it will affect the normal operation of the filter and reduce the power quality.
2、 Main causes of turbine overspeed
The overspeed accident of steam turbine is caused by the fault of the speed regulation and protection system of the steam turbine and its own defects, but it is often directly related to the operation and maintenance. It is analyzed and discussed according to different accident causes and fault links.
1. The speed control system has defects:
The task of the turbine speed control system is not only to ensure the normal operation of the turbine at the rated speed, but also to ensure that the speed rise does not exceed the specified allowable value after the turbine load rejection, so the speed control system is the first measure to prevent the turbine overspeed. If the turbine cannot maintain no-load operation after shedding the load, it may cause overspeed. There are several reasons for excessive speed rise after load rejection of steam turbine.
(1) The governing valve cannot be closed or the steam leakage is large.
(2) The extraction check valve is not tight or refuses to act.
(3) The sluggish rate of the speed control system is too large or the regulating parts are jammed.
(4) The operation mode is unreasonable or improperly adjusted.
(5) The unequal rate of speed regulation system is too large.
(6) Improper dynamic characteristics of speed control system.CT11T7F10PN1 General Electric
(7) Improper setting of the speed control system, such as the adjustment range of the synchronizer and the expansion clearance of the steam distribution mechanism do not meet the requirements.
2. Turbine overspeed protection system fault:
(1) The emergency governor does not operate or the operating speed is too high
The operating speed of the emergency governor is generally 10-12% higher than the rated speed, which is the main protection equipment to protect the steam turbine from excessive increase in speed. In addition, different units have not specified additional protection or electric overspeed device with operating speed slightly higher than the emergency governor. If the emergency governor does not act or acts excessively when the turbine speed rises, the main reasons are:
① The heavy hammer or flying ring guide rod is jammed.
② The dynamic and static parts of the heavy hammer or flying ring are not concentric, and they hold their strength during operation. ③ The spring produces excessive radial deformation under the force, resulting in friction with the hole wall.
④ The gap between the kissing buckle or the striking plate is too large, and the impact can not make the slide valve of the emergency governor act after the impact is flying out.
(2) The slide valve of the emergency governor is jammed and cannot operate.
(3) The automatic main throttle valve and governor valve are jammed.

 

DS200FGPAG1A GE 脉冲放大器板 DS200FGPAG1AHD
531X305NTBAPG1 美国GE 驱动控制 主板模块 端子板531X系列
Reliance Electric 隔离模拟输出模块 57C410A
IC752SPL013 GE 励磁控制接口面板 IC754CSL12CTD
GE IS215ACLEH1B 美国燃机备件 APP控制层板
GE电气IS210AEBIH3BBC燃气轮机系统
GE FANUCA06B-6105-H002数控主板
GE电气FanucHE693THM889BPLC可编程控制系统
GE IC697CPX928中央处理器(CPU)模块96 MHz
GE电气DS200NATOG3A电力输配
美国GE IS200WETAH1AECGE 燃机卡件  厦门雄霸电子
GE/Fanuc电气HE693SNP306AX可编程连接适配器
GE卡件 IS215UCVEH2AE马克印刷电路板
GE IS200TVIBH2B 振动终端板
GE美国IS200TSVOH1B燃机卡
GE美国HE693SDC406通信模块设备
GE美国IC698CPE020L700 MHzCPU
GE美国HE693ADAC420CPLC输入输出
IS200RAPAG1B  GE Mark VI印刷电路板
GE通用电气 IS220UCSAH1A  Mark VIe处理器/控制器
IS200DVIBH1B 印刷电路板 通用GE Mark VI
GE电气DS200TCTGG1AFF电压反馈定标板
PROSOFT MVI56-GEC通信模块Allen-Bradley第三方
GE FANUCA06B-6127-H209电源模块
GE FANUCA06B-6200-H026数控主板
GE FANUCA06B-6096-H307电源模块
GE通用电气 VMIMB1-5576  VMIC通用电气反射存储板
GE美国IS200DSPXH1C/RM风电燃机卡件
GE FANUCA06B-6117-H104电源模块
GE电气FanucHE693DAC420可编程连接
GE美国DS200TCPSG1APE电路板
GE电气HE693ADC420A通信模块设备
GE美国HE693THM806C可编程连接
GE FANUCA06B-6140-H045数控主板
GE美国DS200TCQCG1AHD涡轮机管理系统
GE美国DS200SHCAG1B工厂自动化系统
GE美国IS200EPSMG2AEC电路板
GE电气IS210AEAAH1B重型蒸汽管理
GE FANUCA06B-6117-H210电源模块
GE电气DS200AAHAH1A马克系列背板
GE电气FanucIC695CPU315可编程控制器
GE电气IS200ACLEH1AAA燃气轮机系统
GE FANUCA06B-6151-H015电源模块
GE美国IC698CPE020J浮点微处理器
GE电气DS3800HFXA1D1B电路板
Moog 穆格伺服PI G122-824-002 控制器端子模块 G122824002 库存
MOOG 穆格伺服驱动器 G122-824-001 伺服放大器 G122-829-001
硅存储SST-PFB-GESST-PB3-CLX-RLL电力输配
GE美国HE693SNP900PLC可编程控制系统
GE电气FanucHE693STG884DPLC输入输出
M7iBASE-AC-1GE Juniper 多业务路由器
ARCNET连接板 DS200AAHAG1AD GE通用电气
GE 531X305NTBAPG1 NTB/3TB 终端板
GE DS200TCEAG1ADC处理器卡
GE I/O模块IS220PDIAH1A 336A4940CSP1
GE接线板 IS200TPROH1BCB
GE控制模块IS220PDOAH1A
IS215UCVEH2AB IS215UCVEH2AF GE模块
GE库存DS200SIOBH1ACA电路板控制模块
GE DS200SIOBG1AAA I/O控制板
GE电气VME电路板DS200SIOBH1ABA

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts