Sale!

3625A Safety Instrumented System (SIS)

¥666.00

3625A Safety Instrumented System (SIS)
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

3625A Safety Instrumented System (SIS)
3625A Safety Instrumented System (SIS)
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
What are the types of integrated IO modules3625A Safety Instrumented System (SIS)
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
Technology Oasis • Source: Guangcheng CAN Bus • Author: Guangcheng CAN Bus • 2022-05-09 09:52 • 1740 readings
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
2. Digital output IO, which can send out command signals of digital quantities to control actuators, such as PWM IO, can send pulse signals to control servo motors and stepper motors. In addition to PWM IO, we often use relay output type IO.
3. After discussing digital IO, let”s talk about analog IO. Firstly, analog input IO includes voltage analog input IO, current analog input IO, temperature analog input IO, etc. They collect continuous signals.
4. Finally, there is the output type IO of analog quantity, mainly including voltage analog quantity output type IO and current analog quantity output type IO. Some friends may ask why there is no temperature this time, but there are relatively few applications, mainly based on voltage and current types.3625A Safety Instrumented System (SIS)
Industrial automation solutions, starting with remote IO modules!
The remote IO module is mainly used for collecting analog and digital signals on industrial sites, and can also output analog and digital signals to control equipment. It is possible to expand the input and output ports of data processing equipment such as PLCs and collection instruments. For example, a PLC only has 10 analog input interfaces, but if 30 analog quantities need to be collected on site, remote IO expansion needs to be added.
Furthermore, due to the distance between the equipment and the main control PLC or industrial computer, RS-485 bus is usually used for transmission. There are also some factories with high levels of automation that use industrial Ethernet to control remote IO modules. In the past, when laying lines between equipment and cabinets, people had to connect them one by one, which greatly increased the cost of cables and construction time. Moreover, if the distance was relatively long, they also faced problems such as voltage attenuation. And with the remote IO module, it effectively solves this problem. If your cabinet is 200 meters away from the site and you do not use remote IO, then you need to lay out each signal line for 200 meters. Installing the remote IO module on site can save you a lot of cable costs and reduce the complexity of construction from a cost perspective.
Simply put, sometimes some IO is set up in the on-site device cluster, which can be connected to the PLC through a communication cable to send the signal to any place where it is needed, saving wiring and PLC”s own IO points. Sometimes, the logical “remote” is because the allowed number of “local IO” cannot meet the actual needs, and it needs to be connected to the “remote IO template”, depending on the actual situation.
In addition, the general cabinet room is located on the device site. But some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to send these signals to the control system in the cabinet room.
Why use remote I/O?
1. Because in some industrial applications, it is impossible to install PLCs with local I/O modules near on-site equipment due to harsh environments.
2. When you want to place the I/O module near the field device to eliminate long multi-core cables, you can receive signals from distant sensors and send remote control signals to control valves, motors, and other final actuators. The signal can be transmitted at any distance using various transmission protocols such as Ethernet and Profibus through high-speed media such as twisted pair and fiber optic.
3. Multiple transmission protocols such as Ethernet and Profibus can be used to send signals at any distance on high-speed media such as twisted pair and fiber optic.
The barium rhenium technology MXXT remote IO module uses industrial grade components with a wide working voltage of DC9-36V, which can operate normally within the range of -20~70 ℃. It supports RS485/232 communication mode, and the communication protocol adopts standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. We strive to fully meet the needs of our customers with an electrical and mechanical system that is anti-interference, resistant to harsh environments, and compatible with general use. It has stable performance, reliable quality, short delivery time, and fast response.
Advantages of Barium Rhenium Remote I/O Module
1. It can be controlled by remote commands.
2. Save the cost of using industrial control computers and IO cards, and Ethernet I/O modules can be directly connected to the upper computer system;
3. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
4. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
5. The signal cable of the instrument controller only needs to be connected to the Ethernet I/O module, greatly reducing cable costs and wiring workload.
6. Convenient installation method. Rail installation, high reliability, strong anti-interference ability, and more convenient on-site installation.
Application of Data Acquisition IO Module in Thermal Power Plant System3625A Safety Instrumented System (SIS)
The Ethernet IO module is a data acquisition and control device. It uses Ethernet as a communication method to transmit data from various industrial control sensors and actuators to computers or other devices for management and monitoring. As a modern energy supply base, thermal power plants need to widely apply various intelligent control technologies to improve operational efficiency, reduce costs, and improve safety. In this context, the application of barium rhenium Ethernet IO modules is particularly important.
In the application of thermal power plants, the main function of the barium rhenium Ethernet IO module is to achieve real-time monitoring and control of the production process. By connecting to various sensors and actuators, the barium rhenium Ethernet IO module can collect real-time environmental parameters, machine operation status, and other data of the thermal power plant. By analyzing and processing these data, commanders can understand the operation of the thermal power plant and make corresponding adjustments. Compared to traditional automatic control systems, the barium rhenium Ethernet IO module has the advantages of stronger flexibility, faster reaction speed, and higher accuracy, which can greatly improve the operational efficiency and reliability of thermal power plants.
The real-time monitoring and control of thermal power plants require many capabilities of barium rhenium Ethernet IO modules. Here are several common application scenarios:
Firstly, the barium rhenium module can monitor parameters such as gas flow and water flow in thermal power plants. These parameters are crucial for ensuring the normal operation of the thermal power plant. Once these parameters undergo abnormal changes, the DO channel can be connected to the barium rhenium Ethernet IO module, and the alarm signal will immediately sound to remind the command personnel to handle it. Meanwhile, due to the fact that the barium rhenium Ethernet IO module can collect these data in real-time and transmit it to the monitoring system for recording, it can provide better technical support for quality management in thermal power plants.
Secondly, the barium rhenium Ethernet IO module can also monitor the operating status of mechanical equipment in thermal power plants. This includes parameters such as temperature, pressure, vibration, etc. By monitoring and analyzing these parameters, the barium rhenium Ethernet IO module can detect machine equipment faults in a timely manner, thereby avoiding the expansion of losses. In addition, during machine equipment maintenance, historical data recorded by the barium rhenium Ethernet IO module can be used to develop more scientific and reasonable maintenance plans, reduce maintenance costs, and improve maintenance efficiency.
Finally, the barium rhenium Ethernet IO module can also help thermal power plants achieve distributed control. We can remotely control and monitor multiple areas of the thermal power plant by connecting multiple barium rhenium modules to a network. This not only reduces the on-site debugging of equipment, but also strengthens the evaluation of equipment reliability.
In summary, the barium rhenium Ethernet IO module has unique advantages in real-time monitoring and control of thermal power plants. It can help command personnel monitor machine data in real-time, discover abnormal information, take timely measures to avoid impacts, and improve production efficiency and safety.
Remote IO modules based on Ethernet communication are widely used in the field of industrial IoT
With the development of IIOT (Industrial IOT) industrial Internet of Things technology, many traditional assets need to be connected to the internet to achieve unified data collection, analysis, processing, and storage, breaking the traditional phenomenon of device information silos. Therefore, the MQTT Ethernet IO acquisition module M160T, which supports the Internet of Things protocol, is able to unleash its potential by being compatible with existing devices and able to connect to IoT platforms. The MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart property, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart distribution, smart water conservancy, and many other industries.
Ethernet communication technology is a mature communication technology that has been widely applied. Therefore, Ethernet communication is the first choice for enterprises to connect various assets to the Internet of Things platform. Its reasons are stable and reliable, mature technology, fast transmission speed, and fast construction wiring.3625A Safety Instrumented System (SIS)
For traditional various assets, such as low-voltage distribution rooms, air compressor rooms, property and living pump rooms, street light control, liquid level collection, temperature and humidity collection, etc., through the MQTT Ethernet IO collection module, they can be quickly connected to the Internet of Things platform.
So, what characteristics do MQTT Ethernet IO modules need to have when used in IoT solutions? The details are as follows:
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networking, the Ethernet IO acquisition module must support the TCP Client function, which is not only the TCP client function, so that the Ethernet IO module can actively connect to the IoT platform without the need for complex settings such as peanut shells;
2. Compatible with existing systems:
Support TCP Server and Modbus TCP protocol functions, which can be compatible with traditional upper computer systems or device access of HMI”s TCP client;
3. Access to IoT platforms:
Supports standard MQTT protocol and Modbus TCP protocol, and can be connected to various MQTT protocol IoT platforms such as Huawei Cloud and Alibaba Cloud, or traditional SCADA and DCS systems;
4. Rich IO interfaces and scalability:
There are various types of data to be collected on site, and it is necessary to support the collection of various devices such as 4-20Ma, RS485, DI, DO, etc. At the same time, it is also necessary to have the ability to read RS485 device instrument data or expand the functions of the IO acquisition module;
5. Easy installation method:
The volume of the control box is very limited, so it is necessary to use directly inserted and unplugged wiring terminals, as well as a rail installation method.
6. Industrial grade design
The industrial environment is harsh, and the Ethernet IO module must adopt an industrial grade design to ensure continuous and stable operation in harsh environments.
Through the MQTT Ethernet IO acquisition module, there is no need to replace various existing enterprise assets and the digital transformation of accessing IoT platforms can be quickly achieved. Therefore, the MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart properties, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, smart water conservancy, and many other industries.
How to Build High Channel Density Digital IO Modules for the Next Generation Industrial Automation Controllers
With the rapid development of industrial automation, digital IO modules have become an indispensable part of industrial automation controllers. The digital IO module can connect the controller with external devices, such as sensors, actuators, etc., to achieve monitoring and control of industrial production processes. However, with the continuous development of industrial automation, digital IO modules need to have higher channel density and stronger functionality to meet the needs of new industrial automation controllers. Therefore, it is very important to build high channel density digital IO modules for the next generation of industrial automation controllers.
The digital IO module is one of the most fundamental modules in industrial automation controllers, and its main function is to connect the controller with external devices to achieve signal input and output. The digital IO module usually includes two parts: a digital input module and a digital output module. The digital input module can convert the digital signals of external devices into signals that the controller can read, while the digital output module can convert the digital signals output by the controller into signals that external devices can read. The channel density of a digital IO module refers to the number of digital input or digital output channels provided on the module, which is the input and output capacity of the module.
With the development of industrial automation, digital IO modules need to have higher channel density and stronger functions to meet the needs of new industrial automation controllers. The following are several aspects to consider when building a high channel density digital IO module for the next generation of industrial automation controllers:3625A Safety Instrumented System (SIS)
1. Choose the appropriate communication protocol
Digital IO modules typically communicate with controllers through communication protocols, so choosing a suitable communication protocol is crucial. Common communication protocols include Modbus, Profibus, CANopen, Ethernet, etc. Different communication protocols have different advantages and disadvantages, and selecting a suitable communication protocol requires considering the following factors:
(1) Communication speed: The faster the communication speed, the shorter the response time of the digital IO module, which can process input and output signals faster.
(2) Communication distance: The farther the communication distance, the wider the application range of digital IO modules.
(3) Reliability: The reliability of communication protocols determines the stability and reliability of digital IO modules.
(4) Cost: Different communication protocols have different costs, and suitable communication protocols need to be selected based on actual needs.
2. Choose the appropriate digital IO chip
The digital IO chip is the core component of the digital IO module, and its performance and function directly affect the channel density and function of the digital IO module. Choosing a suitable digital IO chip requires considering the following factors:
(1) Channel density: The channel density of digital IO chips determines the channel density of digital IO modules, and channel density needs to be selected based on actual needs.
(2) Input/output type: Digital IO chips usually support digital input and digital output, and some chips also support functions such as analog input and output, counters, etc.
(3) Speed: The speed of the digital IO chip determines the response speed of the digital IO module, and it is necessary to choose a chip with a faster speed.
(4) Accuracy: The accuracy of digital IO chips determines the signal accuracy of digital IO modules, and it is necessary to choose chips with higher accuracy.
(5) Cost: Different digital IO chips have different costs, and suitable chips need to be selected based on actual needs.
3. Optimize circuit design
The circuit design of digital IO modules has a significant impact on their performance and stability. In order to improve the channel density and functionality of digital IO modules, it is necessary to optimize circuit design, such as:
(1) Using high-speed digital IO chips: Using high-speed digital IO chips can improve the response speed and accuracy of the module.
(2) Adopting anti-interference design: In order to improve the stability of the digital IO module, it is necessary to adopt anti-interference design, such as using filters, isolators, etc.
(3) Using optimized PCB layout: Optimizing PCB layout can reduce noise and interference in digital IO modules, improve module performance and stability.
4. Choose the appropriate shell material and size
Digital IO modules typically need to be installed in cabinets or control cabinets, so choosing the appropriate housing material and size is crucial. The shell material should have good protective and heat dissipation properties to protect the circuits of the digital IO module from external environmental influences. The shell size should be able to adapt to different installation environments, such as cabinets, control cabinets, etc.
5. Optimize software design
The software design of the digital IO module determines its functionality and performance. In order to achieve high channel density and stronger functionality, it is necessary to optimize software design, such as:
(1) Supporting multiple input and output types: Supporting multiple input and output types can meet different application needs, such as digital input and output, analog input and output, counters, etc.
(2) Supporting multiple communication protocols: Supporting multiple communication protocols can adapt to different controllers and application environments.
(3) Support for online debugging and monitoring: Supporting online debugging and monitoring can facilitate user diagnosis and maintenance of modules.
(4) Support for expansion function: Supporting expansion function can increase the functionality and application range of the module while ensuring channel density.
In summary, building a high channel density digital IO module for the next generation of industrial automation controllers requires multiple considerations, including selecting suitable communication protocols, selecting suitable digital IO chips, optimizing circuit design, selecting suitable shell materials and sizes, and optimizing software design. Only by comprehensively considering these factors can a digital IO module with high channel density and stronger functionality be constructed to meet the needs of new industrial automation controllers.
How to assign IO devices to IO controllers?
PROFINET IO system
The PROFINET IO system consists of a PROFINET IO controller and its assigned PROFINET IO devices. After adding IO controllers and IO devices, it is necessary to assign IO controllers to the IO devices to form a basic PROFINET IO system.
Prerequisite requirements
● Already in the network view of STEP 7.
A CPU has been placed (e.g. CPU 1516-3 PN/DP).
● An IO device has been placed (e.g. IM 155-6 PN ST)
Operating Steps (Method 1)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the interface of the IO device.
2. Hold down the left mouse button.
3. Drag the mouse pointer.
The pointer will now use the networking symbol to indicate the “networking” mode. At the same time, you can see a lock character appearing on the pointer
Number. The lock symbol only disappears when the pointer moves to a valid target position.
4. Now, move the pointer to the interface of the desired IO controller and release the left mouse button.
5. Now assign the IO device to the IO controller.
Operating Steps (Method 2)
To assign IO devices to IO controllers, follow these steps:
1. Move the mouse pointer over the word “Unassigned” in the bottom left corner of the IO device icon.
2. Click the left mouse button.
3. Select the IO controller interface to be connected from the available interfaces that appear.
4. Now assign the IO device to the IO controller.

3501TN2 TRICONEX controller
3805H TRICONEX nput/output communication card
4119 TRICONEX nput/output communication card
3625C1 Invensys Triconex system
3481 Safety Instrumented System (SIS)
4352AN TRICONEX nput/output communication card
8312 Invensys Triconex system
3351 TRICONEX controller
2382 TRICONEX nput/output communication card
3723X Safety Instrumented System (SIS)
3351 Invensys Triconex system
3623T Invensys Triconex system
3721 Safety Instrumented System (SIS)
3703E TRICONEX nput/output communication card
3503EN TRICONEX controller
8312 Safety Instrumented System (SIS)
3625C1 TRICONEX controller
3625A TRICONEX nput/output communication card
3700A Safety Instrumented System (SIS)
3503EN TRICONEX nput/output communication card
3664 TRICONEX nput/output communication card
4201 TRICONEX nput/output communication card
8312 TRICONEX controller
3806E Safety Instrumented System (SIS)
2835015 Invensys Triconex system
2401 TRICONEX nput/output communication card
3805E Safety Instrumented System (SIS)
9563-810 TRICONEX controller
3708EN TRICONEX controller
4000098-510 Invensys Triconex system
3008N Invensys Triconex system
9662-610 Invensys Triconex system
3401 Invensys Triconex system
3101 TRICONEX nput/output communication card
3721-C1 TRICONEX nput/output communication card
EPI3382 TRICONEX nput/output communication card
4210 Safety Instrumented System (SIS)
4211 TRICONEX nput/output communication card
3301 Safety Instrumented System (SIS)
4000066-025 Safety Instrumented System (SIS)
3381 TRICONEX nput/output communication card
4352B TRICONEX nput/output communication card
2290614 Safety Instrumented System (SIS)
3704E TRICONEX controller

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts