Sale!

3101 Safety Instrumented System (SIS)

¥666.00

3101 Safety Instrumented System (SIS)
Brand: TRICONEX
Name: Module
Current: 5A
Voltage: 24V
Mode of use: Hot plug implementation
standard: Import
origin: United States

Category:
  • Email:3221366881@qq.com
  • Phone:+86 17750010683
  • Whatsapp:+8617750010683

Description

3101 Safety Instrumented System (SIS)
3101 Safety Instrumented System (SIS)
Module Clips Drive controller servo motor
Contact: Mr. Lai
Wechat:17750010683
Whats app:+86 17750010683
Skype:+86 17750010683
QQ: 3221366881
3221366881@qq.com
What are the characteristics of a demonstration system based on IO Link slave stations
IO Link is an industrial communication interface that is independent of any fieldbus and suitable for simple sensors and actuators at the lowest level of industrial control. The IO Link system includes IO Link devices (such as sensors and actuators), IO Link master stations, and cables for standard sensors. The system structure is shown in Figure 1. For example, when a remote IO module compatible with EtherNet/IP serves as the master station, in addition to standard I/O signals, the module sends and receives configuration data, diagnostic data, or enhanced process data through a pulse modulation process, which is then packaged into EtherNet/IP data packets and finally transmitted to the network master station, usually a PLC. In the above applications, the connection between remote I/O and IO Link devices remains the same as that of traditional discrete devices. The advantage of IO Link mainly lies in its greater information exchange capability, which was previously impossible to achieve with standard I/O devices. Another advantage of IO Link is that it does not rely on any fieldbus, and through any I/O module that complies with the IO Link protocol (including local I/O and remote I/O), IO Link sensors or actuators can be integrated into any fieldbus system.
In order to further study the architecture, communication mechanism, and development application of the IO Link system, an IO Link slave toolkit can be designed and developed, including a universal development module for IO Link, an IO Link analysis tool, and an IO Link slave protocol stack. The IO Link universal development module is the foundation for this work and also serves as a bridge between the IO Link master station and equipment signals. The IO Link analysis tool can help developers and testers analyze communication details to identify and solve problems. The IO Link slave protocol stack is a firmware library that provides a hardware abstraction layer and application program interface, allowing developers to easily and quickly develop IO Link slave products on various microprocessor platforms. The IO Link slave station studied in this article only focuses on digital (button) signal input and digital signal output (indicator light). The design of the IO Link universal development module only needs to be expanded on this basis to have the ability to process analog signals.
The IO Link Master module used in this article, USB IO Link Master, can connect IO Link devices to a PC, which can be configured and tested through the IO Link Device Tool software or demonstrated device functionality. IO Link devices must be described through a device description file (IODD file), which includes a set of XML text files and PNG graphic files, which contain information about device identification, communication characteristics, parameters, process data, and diagnostic data. The portion within the elliptical dashed line in Figure 2 is an IO Link three wire cable, with L+/I – being a 24 V DC power supply and C/Q being a signal line used to transmit process data, diagnostic data, configuration data, etc. The IO Link universal development module is mainly composed of data transceivers and microprocessors. It can process input signals from sensors and transmit information to the IO Link master station. It can also receive and process data information from the master station and transmit it to the actuator. The IO Link analysis tool can help developers view, record, analyze data, and understand communication details. This part of the design is not discussed in this article.
Introduction to IO Link Communication Mode3101 Safety Instrumented System (SIS)
IO Link devices can operate in SIO mode (standard I/O mode) or IO Link mode (communication mode). After power on, the device always operates in SIO mode. The port of the main station has different configuration methods. If configured in SIO mode, the main station considers the port as a standard digital input. If configured in communication mode, the main station will automatically identify the communicable devices for communication.
2.1 Data Types3101 Safety Instrumented System (SIS)
The three basic data types for IO Link communication are periodic data (or process data PD), non periodic data (or service data SD), and event.
The process data (PD) of the device is transmitted periodically in the form of a data frame, while service data (SD) is only exchanged after the master station issues a request. Figure 3 shows a typical IO Link message structure. When an event occurs, the “event flag” of the device is set, and the main station reads the reported event (service data cannot be exchanged during the reading process) upon detecting the setting. Therefore, events such as pollution, overheating, short circuits, or device status can be transmitted to the PLC or visualization software through the main station
2.2 Parameter data exchange
Since service data (SD) must be transmitted through PLC requests, SPDU (Service Protocol Data Unit) is defined. In the main station, requests for read and write services are written to SPDU and transmitted to devices through the IO Link interface.
The general structure of SPDU is shown in Figure 4, and its arrangement order is consistent with the transmission order. The elements in SPDU can take different forms depending on the type of service. SPDU allows access to data objects that are intended for transmission, while Index is used to specify the address of the requested data object on the remote IO Link device. In IO Link, there is a term called direct parameter page, which stores parameter information such as minimum cycle time, supplier ID, and master station commands. The data objects accessible in the direct parameter page can be selectively provided through SPDU.
HMT7742 is an IO Link slave transceiver chip that serves as a bridge between the MCU of external sensors or actuators and the 24V signal line that supports IO Link communication. When the IO Link device is connected to the master station, the master station initializes communication and exchanges data with the MCU. HMT7742 serves as the physical layer for communication.
Due to the fact that the three indicator lights (rated voltage 24 V) controlled by the output port of the MCU are powered by the IO Link power cord, it is necessary to monitor the current on the power cord in order to trigger appropriate corrective measures when the current exceeds a set threshold, such as removing the indicator lights from the IO Link power cord. The current monitoring module uses an INA194 current detection amplifier. As a high detection current detector, INA194 is directly connected to the power supply and can detect all downstream faults. It has a very high common mode rejection ratio, as well as a large bandwidth and response speed. It can amplify the voltage on the induction resistor 5O times and output it to the forward input terminal AIN0 of the MCU internal voltage comparator. When the voltage value of AIN0 exceeds the threshold set at the reverse input terminal, By controlling the low level output of PB0, the indicator LAMP can be cut off from the IO Link power line to achieve overcurrent protection function. This part of the circuit is shown in Figure 6.
MQTT IoT Remote IO Module Based on Ethernet Communication Technology
MQTT IoT Remote IO Module Based on Ethernet Communication Technology
Barium rhenium technology remote IO modules are widely used in IoT scenarios such as intelligent transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, and smart water conservancy.
With the development of IIOT industrial Internet of Things technology, more and more traditional assets need to be connected to the internet, achieving unified data collection and analysis, and breaking the phenomenon of traditional device information silos. The barium rhenium technology remote IO module M160T, which supports IoT protocols, has become an excellent choice for many enterprises to achieve device networking, remote control, and data collection based on the compatibility of existing devices and the accessibility of IoT platforms!
Ethernet communication technology is a mature communication technology because it has the characteristics of stability, reliability, mature technology, fast transmission speed, and fast construction wiring. Due to its wide application, Ethernet communication through the MQTT protocol is the main way for enterprise equipment to go to the cloud. Barium rhenium technology can quickly collect data and control such as air compressor room, property living pump room, street light control, liquid level collection, temperature and humidity collection through Ethernet remote IO module.3101 Safety Instrumented System (SIS)
So, why is the remote IO module of barium rhenium technology widely used in the field of industrial IoT? The specific reasons are as follows.
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networks, the barium rhenium technology remote IO module does not require complex settings such as peanut shells to achieve the Internet of Things. The barium rhenium technology remote IO module needs to support both TCP client and TCP server functions.
2. Compatibility with existing systems:
It supports TCP Server and Modbus TCP protocol functions, and is compatible with device access of traditional upper level systems or HMI TCP clients.
3. Support multiple IoT platforms:
Supports standard MQTT, Modbus TCP, and Modbus RTU over TCP protocols. It can be connected to public cloud IoT platforms and user built MQTT private clouds through the MQTT protocol. It can also be connected to SCADA and DCS systems through Modbus TCP.
4. Rich IO interfaces and scalability:
There are many types of IO for industrial field data collection and replication. The Ethernet IO module of barium rhenium technology supports signal acquisition from various devices such as 4-20Ma, 0-20mA, 0-5V, 0-10V, RS485, DI, DO, PT100, PT1000, pulse input, pulse output, etc. At the same time, it expands the instrument data reading ability of RS485 devices.
5. Convenient installation method:
The volume of industrial on-site control boxes is often very limited, and the barium rhenium technology Ethernet IO module adopts a direct plug-in connection terminal and rail installation method. The compact volume greatly saves space in the control box!
6. Industrial grade design
The industrial environment is harsh, and the remote IO module using barium rhenium technology needs to adopt an industrial grade design, which can work continuously and stably in harsh environments.
Through the use of barium rhenium technology remote IO modules, there is no need to replace existing various enterprise assets, and the digital transition to the Internet of Things platform can be quickly achieved. Therefore, barium rhenium technology remote IO modules are widely used in industrial IoT, such as intelligent real estate, intelligent campus, intelligent factory, intelligent transportation, intelligent water conservancy, intelligent agriculture, intelligent campus, intelligent community, intelligent transportation, and many other industries.
What is the role of distributed IO modules and what are their main applications in
The distributed IO module transmits status signals from the measurement and control field to various measurement and control fields for control. It is mainly used in the industrial field and can also be used for detection of equipment such as air conditioners and motors.
In distributed systems, there are important business data closely related to system operation, as well as data related to nodes, application services, and data services, which are crucial for the normal operation of clusters.
IO on general PLCs is usually closely followed by CPU units, but in order to facilitate connection and maintenance, the concept of distributed IO has been proposed in the industrial field. That is to say, the IO unit can be arranged far away from the PLC CPU unit and communicate through the network communication protocol of the device layer.
The distributed IO module is developed for detecting and implementing remote control of various types of standard analog and switch signals (frequency, pulse, or switch state signals) in the field of measurement and control. The series of modules can digitize the test signal front-end and transmit it to the host through optical fiber; Or transmit the control instructions sent by the host to the controlled device to achieve remote control. Especially suitable for state detection and control of complex electromagnetic environments in power, industrial control, on-site switchgear, and large power equipment.
The role of distributed IO modules:
1. Support 4-way switch digital quantity
2. Supports 8 analog inputs
3. 4 relay outputs, 1 RS485 serial port data acquisition to Ethernet
4. 485 to Ethernet serial server
5. Supports Modbus to TCP/UDP protocol conversion
6. Supports virtual serial ports and interfaces with various configuration software
7. Support 0-5V, 0-10V, 0-30V range acquisition
8. Supports 0-20ma and 4-20ma range acquisition
What are the types of integrated IO modules3101 Safety Instrumented System (SIS)
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
Technology Oasis • Source: Guangcheng CAN Bus • Author: Guangcheng CAN Bus • 2022-05-09 09:52 • 1740 readings
For a programmable logic controller, IO fulfills the responsibilities of data acquisition and instruction output. What control objectives can a PLC achieve, and the quantity and type of IO are crucial. For general integrated PLCs, the number and types of IO interfaces are constant. Some friends may ask, what if you encounter a complex control project with insufficient IO ports in the PLC? Don”t worry, nowadays PLCs have communication interfaces that can be connected to other IO couplers to achieve IO expansion. So, what are the types of IO modules that we can integrate in our daily lives? Actually, it can be mainly divided into four categories, namely:
1. Digital signal acquisition IO can achieve discontinuous signal acquisition, and a typical IO type is a counter input IO module.
2. Digital output IO, which can send out command signals of digital quantities to control actuators, such as PWM IO, can send pulse signals to control servo motors and stepper motors. In addition to PWM IO, we often use relay output type IO.
3. After discussing digital IO, let”s talk about analog IO. Firstly, analog input IO includes voltage analog input IO, current analog input IO, temperature analog input IO, etc. They collect continuous signals.
4. Finally, there is the output type IO of analog quantity, mainly including voltage analog quantity output type IO and current analog quantity output type IO. Some friends may ask why there is no temperature this time, but there are relatively few applications, mainly based on voltage and current types.3101 Safety Instrumented System (SIS)
Industrial automation solutions, starting with remote IO modules!
The remote IO module is mainly used for collecting analog and digital signals on industrial sites, and can also output analog and digital signals to control equipment. It is possible to expand the input and output ports of data processing equipment such as PLCs and collection instruments. For example, a PLC only has 10 analog input interfaces, but if 30 analog quantities need to be collected on site, remote IO expansion needs to be added.
Furthermore, due to the distance between the equipment and the main control PLC or industrial computer, RS-485 bus is usually used for transmission. There are also some factories with high levels of automation that use industrial Ethernet to control remote IO modules. In the past, when laying lines between equipment and cabinets, people had to connect them one by one, which greatly increased the cost of cables and construction time. Moreover, if the distance was relatively long, they also faced problems such as voltage attenuation. And with the remote IO module, it effectively solves this problem. If your cabinet is 200 meters away from the site and you do not use remote IO, then you need to lay out each signal line for 200 meters. Installing the remote IO module on site can save you a lot of cable costs and reduce the complexity of construction from a cost perspective.
Simply put, sometimes some IO is set up in the on-site device cluster, which can be connected to the PLC through a communication cable to send the signal to any place where it is needed, saving wiring and PLC”s own IO points. Sometimes, the logical “remote” is because the allowed number of “local IO” cannot meet the actual needs, and it needs to be connected to the “remote IO template”, depending on the actual situation.
In addition, the general cabinet room is located on the device site. But some control signals, such as emergency stop and bypass, are implemented in the control room, so remote IO modules need to be used to send these signals to the control system in the cabinet room.
Why use remote I/O?
1. Because in some industrial applications, it is impossible to install PLCs with local I/O modules near on-site equipment due to harsh environments.
2. When you want to place the I/O module near the field device to eliminate long multi-core cables, you can receive signals from distant sensors and send remote control signals to control valves, motors, and other final actuators. The signal can be transmitted at any distance using various transmission protocols such as Ethernet and Profibus through high-speed media such as twisted pair and fiber optic.
3. Multiple transmission protocols such as Ethernet and Profibus can be used to send signals at any distance on high-speed media such as twisted pair and fiber optic.
The barium rhenium technology MXXT remote IO module uses industrial grade components with a wide working voltage of DC9-36V, which can operate normally within the range of -20~70 ℃. It supports RS485/232 communication mode, and the communication protocol adopts standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. We strive to fully meet the needs of our customers with an electrical and mechanical system that is anti-interference, resistant to harsh environments, and compatible with general use. It has stable performance, reliable quality, short delivery time, and fast response.
Advantages of Barium Rhenium Remote I/O Module
1. It can be controlled by remote commands.
2. Save the cost of using industrial control computers and IO cards, and Ethernet I/O modules can be directly connected to the upper computer system;
3. Replacing 4-20mA signal transmission with 10/100MHz Ethernet transmission has improved transmission speed;
4. Replacing various instrument controller signal lines with an Ethernet cable reduces the attenuation of remote signal transmission;
5. The signal cable of the instrument controller only needs to be connected to the Ethernet I/O module, greatly reducing cable costs and wiring workload.
6. Convenient installation method. Rail installation, high reliability, strong anti-interference ability, and more convenient on-site installation.
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
TRICONEX 3805E Invensys can accommodate the backplane of previous modules
Fault tolerance in the TRICONEX 3805E is achieved through the the third mock examination redundancy (TMR) architecture. Tricon can provide error free and uninterrupted control in the event of hard faults or internal or external transient faults in components. Tricon adopts a completely triple architecture design, from the input module to the main processor and then to the output module. Each I/O module contains three independent branch circuits. Each pin on the input module reads process data and passes this information to their respective main processors. The three main processors communicate with each other using a proprietary high-speed bus system called TriBus. Every scan, the three main processors synchronize and communicate with their two neighbors through TriBus. Tricon votes on digital input data, compares output data, and sends copies of analog input data to each main processor. The main processor executes user written applications and sends the output generated by the application to the output module. In addition to voting on input data, TriBus also votes on output data. This is done on the output module as close to the field as possible to detect and compensate for any errors between the Tricon voting and the final output driven to the field.
The TRICONEX 3805E system typically consists of the following typical modules: [2]
Main processor modules (three).3101 Safety Instrumented System (SIS)
Communication module.
Input and output modules: can be analog and/or digital, can work independently, or can be hot backup (backup).
Power module (redundant).3101 Safety Instrumented System (SIS)
A backplane (chassis) that can accommodate previous modules.
System cabinet: One or more chassis can be compressed into one cabinet.
Organize cabinets to adapt and standardize interface connections between on-site instruments and Triconex system cabinets.
Human Machine Interface (HMI) for monitoring events.
Engineering Workstation (EWS) for programming. Monitoring, troubleshooting, and updating.
The remote IO module is designed according to the demanding industrial application environment requirements, embedded with a 32-bit high-performance microprocessor MCU, to meet various combinations of digital, analog, and thermal resistance IO modules. The communication protocol of the remote IO module adopts the standard Modbus TCP protocol, Modbus RTU over TCP protocol, and MQTT protocol. The remote IO module supports a wide working voltage of DC9-36V and has anti reverse protection function. It is equipped with a built-in watchdog and comprehensive lightning protection and anti-interference measures to ensure reliability.
The remote IO module supports 1 isolated 10/100M adaptive Ethernet interface with 15KV ESD protection, optocoupler isolated digital input, and supports dry wet contact input. The first channel can be used as pulse counting, supporting high-speed pulse and low-speed pulse modes. The default is high-speed pulse frequency with a maximum of 700KHz, and the optional low-speed pulse frequency with a maximum of 10KHz; DO output supports transistor Sink output, with the first channel available for high-speed pulse output, supporting pulse frequencies of 10Hz~300KHz; The remote IO module supports isolated 12 bit resolution analog input: 0-5V, 0-10V, 0-20mA, 4-20mA differential input; 1 channel RS485 communication interface, supporting standard Modbus RTU protocol for expansion; The thermal resistance RTD input supports two types: PT100 and PT1000;
What are the common types of IO extension modules? How much does an IO expansion module usually cost?
2. Analog Input Output Module: A module used to process and monitor analog signal input and output. Common analog input and output modules include modules based on resistors, transistors, and optocouplers.
3. Communication Interface Module: A module used to achieve communication between devices. Common communication interface modules include modules based on interfaces such as RS232, RS485, Ethernet, and CAN.
4. Special Function Module: A module used to implement specific functions. For example, the PWM (Pulse Width Modulation) module is used to control the speed and direction of the motor, and the counting module is used to achieve counting functions.
The price of IO expansion modules may vary depending on different brands, models, and functions.
Generally speaking, the price of more basic IO expansion modules ranges from tens to hundreds of yuan, while the price of IO expansion modules with more complex functions and stronger performance may be higher.
For example, the Io extension module ET1010 recently released by Zongheng Intelligent Control Company costs only 169 yuan per unit, and supports functions such as front-end and back-end cascading, sensorless expansion, and plug and play. It can be purchased in bulk or applied for a free trial address; The specific prices of these IO modules need to be queried and compared based on the specific modules you need.
Application of Data Acquisition IO Module in Thermal Power Plant System3101 Safety Instrumented System (SIS)
The Ethernet IO module is a data acquisition and control device. It uses Ethernet as a communication method to transmit data from various industrial control sensors and actuators to computers or other devices for management and monitoring. As a modern energy supply base, thermal power plants need to widely apply various intelligent control technologies to improve operational efficiency, reduce costs, and improve safety. In this context, the application of barium rhenium Ethernet IO modules is particularly important.
In the application of thermal power plants, the main function of the barium rhenium Ethernet IO module is to achieve real-time monitoring and control of the production process. By connecting to various sensors and actuators, the barium rhenium Ethernet IO module can collect real-time environmental parameters, machine operation status, and other data of the thermal power plant. By analyzing and processing these data, commanders can understand the operation of the thermal power plant and make corresponding adjustments. Compared to traditional automatic control systems, the barium rhenium Ethernet IO module has the advantages of stronger flexibility, faster reaction speed, and higher accuracy, which can greatly improve the operational efficiency and reliability of thermal power plants.
The real-time monitoring and control of thermal power plants require many capabilities of barium rhenium Ethernet IO modules. Here are several common application scenarios:
Firstly, the barium rhenium module can monitor parameters such as gas flow and water flow in thermal power plants. These parameters are crucial for ensuring the normal operation of the thermal power plant. Once these parameters undergo abnormal changes, the DO channel can be connected to the barium rhenium Ethernet IO module, and the alarm signal will immediately sound to remind the command personnel to handle it. Meanwhile, due to the fact that the barium rhenium Ethernet IO module can collect these data in real-time and transmit it to the monitoring system for recording, it can provide better technical support for quality management in thermal power plants.
Secondly, the barium rhenium Ethernet IO module can also monitor the operating status of mechanical equipment in thermal power plants. This includes parameters such as temperature, pressure, vibration, etc. By monitoring and analyzing these parameters, the barium rhenium Ethernet IO module can detect machine equipment faults in a timely manner, thereby avoiding the expansion of losses. In addition, during machine equipment maintenance, historical data recorded by the barium rhenium Ethernet IO module can be used to develop more scientific and reasonable maintenance plans, reduce maintenance costs, and improve maintenance efficiency.
Finally, the barium rhenium Ethernet IO module can also help thermal power plants achieve distributed control. We can remotely control and monitor multiple areas of the thermal power plant by connecting multiple barium rhenium modules to a network. This not only reduces the on-site debugging of equipment, but also strengthens the evaluation of equipment reliability.
In summary, the barium rhenium Ethernet IO module has unique advantages in real-time monitoring and control of thermal power plants. It can help command personnel monitor machine data in real-time, discover abnormal information, take timely measures to avoid impacts, and improve production efficiency and safety.
Remote IO modules based on Ethernet communication are widely used in the field of industrial IoT
With the development of IIOT (Industrial IOT) industrial Internet of Things technology, many traditional assets need to be connected to the internet to achieve unified data collection, analysis, processing, and storage, breaking the traditional phenomenon of device information silos. Therefore, the MQTT Ethernet IO acquisition module M160T, which supports the Internet of Things protocol, is able to unleash its potential by being compatible with existing devices and able to connect to IoT platforms. The MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart property, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart distribution, smart water conservancy, and many other industries.
Ethernet communication technology is a mature communication technology that has been widely applied. Therefore, Ethernet communication is the first choice for enterprises to connect various assets to the Internet of Things platform. Its reasons are stable and reliable, mature technology, fast transmission speed, and fast construction wiring.3101 Safety Instrumented System (SIS)
For traditional various assets, such as low-voltage distribution rooms, air compressor rooms, property and living pump rooms, street light control, liquid level collection, temperature and humidity collection, etc., through the MQTT Ethernet IO collection module, they can be quickly connected to the Internet of Things platform.
So, what characteristics do MQTT Ethernet IO modules need to have when used in IoT solutions? The details are as follows:
1. Actively connect to cloud platforms:
Based on the characteristics of Ethernet communication networking, the Ethernet IO acquisition module must support the TCP Client function, which is not only the TCP client function, so that the Ethernet IO module can actively connect to the IoT platform without the need for complex settings such as peanut shells;
2. Compatible with existing systems:
Support TCP Server and Modbus TCP protocol functions, which can be compatible with traditional upper computer systems or device access of HMI”s TCP client;
3. Access to IoT platforms:
Supports standard MQTT protocol and Modbus TCP protocol, and can be connected to various MQTT protocol IoT platforms such as Huawei Cloud and Alibaba Cloud, or traditional SCADA and DCS systems;
4. Rich IO interfaces and scalability:
There are various types of data to be collected on site, and it is necessary to support the collection of various devices such as 4-20Ma, RS485, DI, DO, etc. At the same time, it is also necessary to have the ability to read RS485 device instrument data or expand the functions of the IO acquisition module;
5. Easy installation method:
The volume of the control box is very limited, so it is necessary to use directly inserted and unplugged wiring terminals, as well as a rail installation method.
6. Industrial grade design
The industrial environment is harsh, and the Ethernet IO module must adopt an industrial grade design to ensure continuous and stable operation in harsh environments.
Through the MQTT Ethernet IO acquisition module, there is no need to replace various existing enterprise assets and the digital transformation of accessing IoT platforms can be quickly achieved. Therefore, the MQTT Ethernet IO acquisition module will be widely used in industrial IoT, such as smart properties, smart parks, smart factories, smart transportation, smart water conservancy, smart agriculture, smart campuses, smart communities, smart power distribution, smart water conservancy, and many other industries.

DKC11.1-040-7-FW
DKC03.3-040-7-FW
DKC02.3-100-7-FW
DKC02.3-100-7-FW
DKC02.3-100-7-FW
DKC02.3-040-7-FW
DDS02.2-W200-BE24-02-FW
DDS02.2-A100-BE23-01-FW
CSH01.3C-ET-ENS-NNN-CCD-NN-S-NN-FW
CSH01.3C-ET-EN2-NNN-CCD-S2-S-NN-FW
CSB02.1B-ET-EC-NN-S4-NN-NN-FW
CSB02.1B-ET-EC-NN-S4-NN-NN-FW
CSB02.1A-ET-EC-EC-NN-NN-NN-FW
CSB01.1N-PB-ENS-NNN-NN-S-NN-FW
CSB01.1C-SE-ENS-NNN-NN-S-NN-FW
CSB01.1C-S3-ENS-NNN-L2-S-NN-FW
CSB01.1C-PB-ENS-NNN-L2-S-NN-FW
CML45.1-3P-500-NA-NNNN-NW
CML40.2-SP-330-NA-NNNN-NW
CDB02.1B-ET-EC-EC-NN-L3-L3-NN-NN-FW
BTV04.2GN-FW
608750113
608750112
REXROTH R911328500
R911311914
PPC-R22.1N-N-N-V2-NN-FW
VT-VSPA1-1-11
VT-VPCD-1-16/V0/1-P-1
VT-HNC100-1-23/W-08-P-0
VT2000-52
SE352
R911171949-AG1
PSI6500.100-W1
PPC-R22.1N-T-Q1-P2-NN-FW
msm031c-0300-nn-m0-ch0
MSK076C-0450-NN-S1-UP0-NNNN
MSK061C-0300-NN-M1-UP1-NNNN
MSK050C-0300-NN-M1-UG1-NNNN
MSK040C-0450-NN-M1-UG1-NNNN
MKD090B-035-KG1-KN
MKD071B-061-KP1-KN
MKD071B-061-KG1-KN
MKD071B-061-KG1-KN
MKD071B-035-GP0-KN
MKD025B-144-KP0-UN
MKD025B-144-KG1-UN
MHD093A-035-PG0-BA
MHD071B-061-PG0-UN
MHD041B-144-PG1-UN
MHD041B-144-PG1-UN
MDD065D-N-060-N2M-095PB1
MA4/200-7301-M
KE310
KDA3.2-100-3-A00-W1
HMS02.1N-W0028-A-07-NNNN
HMS01.1N-W0070-A-07-NNNN
HDS04.2-W200N-HS79-01-FW
HCS02-1E-W0054-A-03-NNNN
HCS02.1E-W0070-A-03-NNNN
DKC11.1-040-7-FW
DKC02.3-100-7-FW
DKC02.3-040-7-FW
DKC01.3-012-3-MGP-01VRS
BTV04.2GN-FW
608750113
608750112
VT-VACAP-500-20/V0
0608750113(LT-354)
0608750112(LT-353)
MKD112C-024-KP3-BN
GKR04-2MHGR-071C32
MKD112B-024-GP0-BN
MHD090B-058-NG0-UN

 

Company advantage service:
1.Has been engaged in industrial control industry for a long time, with a large number of inventories.
2.Industry leading, price advantage, quality assurance
3.Diversified models and products, and all kinds of rare and discontinued products
4.15 days free replacement for quality problems
All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc

ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon controlled 5SHY 3BHB01 3BHE00 3HNA00 DSQC series
BENTLY — 3500 system/proximitor, front and rear card, sensor, probe, cable 3500/20 3500/61 3500/05-01-02-00-001 3500/40M 176449-01 3500/22M 138607-01
Emerson — modbus card, power panel, controller, power supply, base, power module, switch 1C31,5X00, CE400, A6500-UM, SE3008,1B300,1X00,
EPRO — PR6423 PR6424 PR6425 PR6426 PR9376 PR9268 Data acquisition module, probe, speed sensor, vibration sensor
FOXBORO — FCP270 FCP280 FCM10EF FBM207 P0914TD CP40B FBI10E FBM02 FBM202 FBM207B P0400HE Thermal resistance input/output module, power module, communication module, cable, controller, switch
GE —- IS200/215/220/230/420 DS200/215 IC693/695/697/698 VMICPCI VMIVME 369-HI-R-M-0-0-E 469 module, air switch, I/O module, display, CPU module, power module, converter, CPU board, Ethernet module, integrated protection device, power module, gas turbine card
HIMA — F3 AIO 8/4 01 F3231 F8627X Z7116 F8621A 984862160 F3236 F6217 F7553 DI module, processor module, AI card, pulse encoder
Honeywell — Secure digital output card, program module, analog input card, CPU module, FIM card
MOOG — D136-001-007 Servo valve, controller, module
NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module, Card
Westinghouse — RTD thermal resistance input module, AI/AO/DI/DO module, power module, control module, base module
Woodward — 9907-164 5466-258 8200-1300 9907-149 9907-838 EASYGEN-3500-5/P2 8440-2145 Regulator, module, controller, governor
YOKOGAWA – Servo module, control cabinet node unit

Main products:
PLC, DCS, CPU module, communication module, input/output module (AI/AO/DI/DO), power module, silicon controlled module, terminal module, PXI module, servo drive, servo motor, industrial display screen, industrial keyboard, controller, encoder, regulator, sensor, I/O board, counting board, optical fiber interface board, acquisition card, gas turbine card, FIM card and other automatic spare parts